*Promethean Innovations* # Every watt of compute ends as heat. We make sure it lands somewhere useful. Data centers spend up to 40% of their power getting rid of heat.[1] The rest of the world spends almost half its energy making it.[2] Promethean closes the loop: compute that heats, heat that pays. - [Meet Heatoshi](https://promethean.is/heatoshi) - [See commercial installations](https://promethean.is/commercial) - [Run your own numbers](https://calc.heatoshi.xyz/) Sources: 1. [US Department of Energy, COOLERCHIPS announcement (2022)](https://www.energy.gov/articles/doe-announces-42-million-develop-high-performance-cooling-systems-data-centers) 2. [IEA, Renewables 2025, renewable heat](https://www.iea.org/reports/renewables-2025/renewable-heat) *The opportunity* ## We throw away two of our most valuable resources. ### Compute is growing fast Data centers consume around 400 TWh a year and are expected to double by 2030.[3] Cooling that hardware takes up to 40% of the power draw and cost.[1] ### Heat demand is enormous Heat is almost half of all the energy the world uses,[2] and space heating alone is a third of what a US commercial building burns.[4] Almost none of it is reused heat. ### Big deployments are slow A conventional data center is all-or-nothing. Approval takes months or years, and it may not come. Smaller, distributed deployments carry less risk and reach market faster. Sources: 3. [IEA, Energy and AI (2025)](https://www.iea.org/reports/energy-and-ai) 4. [US EIA, energy use in commercial buildings (2018)](https://www.eia.gov/energyexplained/use-of-energy/commercial-buildings.php) *The concept* ## Compute is a heat source. Server-grade hardware sits in homes and businesses and serves as the heat source. Our patent-pending technology captures that heat and delivers it as comfort or process heat. The computation earns rewards, and the rewards offset the electricity bill. 1. **Compute does paid work.** A work provider assigns the load. The chips release heat as they run. 2. **We capture it.** Our patent-pending hydronic system routes the heat through exchangers, not out to the air. 3. **Heat goes where you need it.** Comfort heat, process heat, or a dry cooler when nothing needs warming. 4. **The work pays.** Rewards for the computation offset the electricity it uses. *Two ways in* ### [Heatoshi](https://promethean.is/heatoshi) Our retail product. The world's first self-contained residential hydronic heater based on computationally generated heat. For homes, offices, pools, and barns. ### [Commercial installations](https://promethean.is/commercial) Engineered heat-recovery compute systems for hotels, warehouses, food production, multi-unit buildings, and other sites where heat is a line item. *Who we are* ## Built by people who have commissioned the boilers, shipped the software and run the kitchen. We believe the energy transition is mostly a plumbing problem: the heat already exists, it is just in the wrong place. We would rather fix that than argue about it. Most heat-reuse projects spend their budget moving heat across a city. We skip the trip and put the compute into a hydronic loop someone already pays to run. That is a design, build and commission problem. We have done each for a living. Between us: a licensed Professional Engineer who spent a decade commissioning mechanical, electrical, plumbing and fire-protection systems and wrote the study guide for Decarbonization Professionals. Engineering leadership at businesses that scaled to nine-figure revenue. A production lead who went from owning a bakery to building commercial fusion generators. And the go-to-market that turns a heater into a business. Every one of us has owned a business and signed the front of a check. That is the whole job.